PRODUCT SPECIFICATIONS
Mecer 1000VA On-Line Tower UPS (ME-1000-WPTU)
- Capacity: 1000VA / 800W,
Battery Type: 12V/9Ah,
Frequency Range: 40Hz ~ 70 Hz
Includes AVR, Monitoring Software, Cables & Built-in Surge Protection,
Black Colour
Overview
Mecer 1000VA On-Line Tower UPS (ME-1000-WPTU) has a wide input voltage range and an available converter mode.
Features
This UPS can charge up to 90% in battery capacity within a 4 hour period. This UPS is generator compatible and the Waveform is Pure Sinewave.
Note
A UPS is not designed to provide continuous power, it allows a computer or device to keep running for a short period of time when the primary power source is lost.
Specifications:
Phase
Single-phase with ground
Capacity
1000 VA / 800 W
Input
Voltage Range
Low Line Transfer
160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5% (Ambient Temp. < 35°C) (based on load percentage 100% - 80% / 80% - 70% / 70-60 % / 60% - 0)
Low Line Comeback
175 VAC / 155 VAC / 135 VAC / 125 VAC ± 5% (Ambient Temp.
High Line Transfer
300 VAC ± 5%
High Line Comeback
290 VAC ± 5%
Frequency Range
40HZ ~ 70 HZ
Power Factor
? 0.99 @ nominal voltage
Output
Output Voltage
200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)
± 1%
Frequency Range (Synchronised Range)
47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode)
50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz
Current Crest Ratio
3:1
Harmonic Distortion
? 3 % THD (Linear Load), ? 6 % THD (non-linear load)
Transfer Time
AC Mode to Batt. Mode
Zero
Inverter to Bypass
4 ms (Typical)
Waveform (Batt. Mode)
Pure Sinewave
Efficiency
AC Mode
88%
Battery Mode
83%
Battery
Battery Type
12 V 9 Ah
Numbers
2
Typical Recharge Time
4 hours to recover to 90% capacity
Charging Current (max.)
.
Charging Voltage
27.4 VDC ± 1%
Indicators
LCD Panel
UPS status, Load level, Battery level, Input/output Voltage, Discharge timer and Fault Conditions
Alarm
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
Physical
Dimension, D x W x H (mm)
282 x 145 x 220
Net Weight (kgs)
9.8
Environment
Humidity
20-90 % RH @ 0-40°C (non-condensing)
Noise Level
Less than 50dB @ 1 Meter
Management
Smart RS-232/USB
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix and Mac
Optional SNMP
Power management from SNMP manager and web browser
What's in the box
1xMecer 1000VA On-Line Tower UPS (ME-1000-WPTU)
1xProduct Info
- Shipping Local National International